Web: www.AdvantageEngineering.com • Temperature Control Units Water & Oil 30° - 500°F • Portable Chillers Air & Water-Cooled 20° - 70°F • Central Chillers Air & Water-Cooled Packages & Modules 20° - 70°F • Pump Tank Stations Chilled or Tower Water 200 - 3600 gallons • Cooling Tower Cells 45 - 540 tons • Filters
Phone: 317-887-0729
REGAL SERIES - Air-Cooled ADVANTAGE Regal high temperature oil units are designed to supply up to 500°F of temperature stabilized heat transfer fluid to applications such as plastic molding, chemical processing and many others. Air-cooled units need no water hook-ups. Both heating only and heating and cooling models are available.
• • • • • •
PROCESS TEMPERATURES: 100°F to 500°F AVAILABLE PUMP HP: 1 to 3 AVAILABLE HEATER KW: 12 to 24 COOLING OPTION: Air-cooled via heat exchanger CONTROL INSTRUMENT: Microprocessor based STANDARD DIMENSIONS: 44” x 16” x 24” (HxWxD)
• Heat Exchangers
WARRANTIES 1 Year covering the entire machine. 4 Years control instrument
All models feature a high volume centrifugal pump with air-cooled pump seal. Models that include the optional cooling feature are equipped with a high temperature air-cooled heat exchanger to provide process cooling. When required, a valve opens introducing cooled fluid into the process while the fan exhausts the heat to the environment. The fan runs continuously providing a cool fluid reserve in the heat exchanger for rapid cooling on demand.
STANDARAD FEATURES TANKS: • Large capacity expansion tank • NPT process connections • Process line shut-off valves • Oil level sight glass • Air operated mold purge circuit • Fluid drain valve • Fluid fill port PUMP: • Low pressure centrifugal pump • Cast iron casing • Bronze pump impeller • Air-cooled pump seal • Stainless steel motor shaft HEATER: • Flanged bolt-in mount • Vertical orientation • Steel heater sheath • Mercury heater contactor CABINETRY/FRAME: • Stainless steel cabinetry • Hinged electrical cover • Portable, on casters • Galvanized steel base
PRESSURE GAUGE: • To process CONTROL INSTRUMENT: • Advantage LE WARRANTY: • 1 year parts and labor • See #W-700 for details
OPTIONS INSTRUMENTATION: • HE control instrument • Remote display (HE) • SPI communications cable - 20ʼ (LE & HE) SYSTEM ALARMS: • Audible alarm • Visual/audible alarm beacon ELECTRICAL: • Nema 12 construction • Special electrics
LIMIT DEVICES: • Motor overload relay • High temperature limit • Fused control circuit ELECTRICAL: • Process pump motor starter • Fused transformer • 10ʼ power cord installed • 110 volt alarm output • 5 kA RMS SSCR
RK-1230HCA
APPLICATIONS Regal Series temperature control units can be used on a variety of process applications that require 100°F to 500°F process temperatures.
Molds & Dies
Nozzles, Barrels & Tools
Heat Exchangers
Troughs & Tanks
Rolls
Radiators and Air Coils
Jacketed Vessels and Mixers
Lasers
SPECIFICATIONS H = Heating Only
SPECIFICATIONS RKHEATER1 PROCESS PUMP
FULL LOAD AMPERAGE @3ø/60hz2 DIMENSIONS
CONNECTIONS WEIGHTS (lbs)
KW HP GPM PSI 230 volt 460 volt 575 volt Height Width Depth T/F3 Shipping4
1230H/HCA 12 1 30 24 34.8 17.9 14.3 60' 24' 52' 1' 600
1245H/HCA 12 11/2 45 26 36.4 18.7 14.9 60' 24' 52' 1' 625
1250H/HCA 12 2 50 28 38.0 19.5 15.6 60' 24' 52' 1' 630
1645H/HCA 16 11/2 45 26 47.0 23.5 18.8 60' 24' 52' 1' 700
CONTROL INSTRUMENTS
HCA = Heating & Cooling Air-Cooled 1650H/HCA 16 2 50 28 49.0 24.5 19.6 60' 24' 52' 1' 725
1660H/HCA 16 3 60 26 51.0 25.5 20.4 60' 24' 52' 1' 730
2460H/HCA 24 3 60 26 71.0 35.5 28.4 60' 24' 52' 1' 850
Standard
ʻLEʼ INSTRUMENT - up to 500°F: • Temperature display for to process, from process and setpoint temperatures • Status lights for power, pump heat, cool and alarm • Error lights for pump overload, and high temperature • Pump start switch • Unit on/off toggle switch • Soft key operators
1. Derate heater output by 25% for 208/3/60 operation. 2. Consult factory for 50hz operations. 3. T - to process; F - from process. 4. Approximate shipping weight.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Upgrade!
ʻHEʼ INSTRUMENT - up to 500°F: • Continuous to process temperature display • Selectable from process temperature display • Temperature display in °F or °C • Continuous setpoint temperature display • Setup display for temperature, network and machine • Capacity display for heat, cool • Ok-fault status display for temperature deviation, probe, high temperature, pump overload and phase • Alarm display • Communications display • SPI communications • Soft key operators
17 18 19 20 21
22 23
24 25
26
# 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
-
18 19 20 21 22 23
-
24 25 26 -
Phone: 317-887-0729
Description Fluid fill port Fluid pressure gauge Expansion tank Heat exchanger Cooling fan and shroud Fluid level sight glass Control Instrument Fan motor Process connections Cooling valve Transformer (with fuse) From process sensor To process sensor Discharge cylinder Power entry terminal block Suction cylinder Centrifugal pump with air-cooled seal Mercury heater contactor Pump motor starter and over load Pump motor Caster Lift-off access panel To process connection and shut-off valve From process connection and shut-off valve Air connection and valve for mold purge Unit drain
Model Designator for Regal Series Temperature Control Units RK - 1230HCA Regal Series Heater KW Pump GPM
Mode: H : Heating Only HC : Heating & Cooling HCA : Air-Cooled
Web: www.AdvantageEngineering.com
TEMPERATURE CONTROLLERS • PORTABLE CHILLERS • CENTRAL CHILLERS • PUMP TANK STATIONS • TOWER SYSTEMS • FILTERS
ADVANTAGE ENGINEERING, INC. 525 East Stop 18 Road Greenwood, IN 46142 phone: 317-887-0729 web site: www.AdvantageEngineering.com email: [email protected]
©2013 ADVANTAGE ENGINEERING, INC.
fax: 317-881-1277
Form #ADV-544 11/03 updated 01/24/2013
SINCE PRODUCT INNOVATION AND IMPROVEMENT IS OUR CONSTANT GOAL, ALL FEATURES AND SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR LIABILITY.
Phone: 317-887-0729
REGAL SERIES - Air-Cooled ADVANTAGE Regal high temperature oil units are designed to supply up to 500°F of temperature stabilized heat transfer fluid to applications such as plastic molding, chemical processing and many others. Air-cooled units need no water hook-ups. Both heating only and heating and cooling models are available.
• • • • • •
PROCESS TEMPERATURES: 100°F to 500°F AVAILABLE PUMP HP: 1 to 3 AVAILABLE HEATER KW: 12 to 24 COOLING OPTION: Air-cooled via heat exchanger CONTROL INSTRUMENT: Microprocessor based STANDARD DIMENSIONS: 44” x 16” x 24” (HxWxD)
• Heat Exchangers
WARRANTIES 1 Year covering the entire machine. 4 Years control instrument
All models feature a high volume centrifugal pump with air-cooled pump seal. Models that include the optional cooling feature are equipped with a high temperature air-cooled heat exchanger to provide process cooling. When required, a valve opens introducing cooled fluid into the process while the fan exhausts the heat to the environment. The fan runs continuously providing a cool fluid reserve in the heat exchanger for rapid cooling on demand.
STANDARAD FEATURES TANKS: • Large capacity expansion tank • NPT process connections • Process line shut-off valves • Oil level sight glass • Air operated mold purge circuit • Fluid drain valve • Fluid fill port PUMP: • Low pressure centrifugal pump • Cast iron casing • Bronze pump impeller • Air-cooled pump seal • Stainless steel motor shaft HEATER: • Flanged bolt-in mount • Vertical orientation • Steel heater sheath • Mercury heater contactor CABINETRY/FRAME: • Stainless steel cabinetry • Hinged electrical cover • Portable, on casters • Galvanized steel base
PRESSURE GAUGE: • To process CONTROL INSTRUMENT: • Advantage LE WARRANTY: • 1 year parts and labor • See #W-700 for details
OPTIONS INSTRUMENTATION: • HE control instrument • Remote display (HE) • SPI communications cable - 20ʼ (LE & HE) SYSTEM ALARMS: • Audible alarm • Visual/audible alarm beacon ELECTRICAL: • Nema 12 construction • Special electrics
LIMIT DEVICES: • Motor overload relay • High temperature limit • Fused control circuit ELECTRICAL: • Process pump motor starter • Fused transformer • 10ʼ power cord installed • 110 volt alarm output • 5 kA RMS SSCR
RK-1230HCA
APPLICATIONS Regal Series temperature control units can be used on a variety of process applications that require 100°F to 500°F process temperatures.
Molds & Dies
Nozzles, Barrels & Tools
Heat Exchangers
Troughs & Tanks
Rolls
Radiators and Air Coils
Jacketed Vessels and Mixers
Lasers
SPECIFICATIONS H = Heating Only
SPECIFICATIONS RKHEATER1 PROCESS PUMP
FULL LOAD AMPERAGE @3ø/60hz2 DIMENSIONS
CONNECTIONS WEIGHTS (lbs)
KW HP GPM PSI 230 volt 460 volt 575 volt Height Width Depth T/F3 Shipping4
1230H/HCA 12 1 30 24 34.8 17.9 14.3 60' 24' 52' 1' 600
1245H/HCA 12 11/2 45 26 36.4 18.7 14.9 60' 24' 52' 1' 625
1250H/HCA 12 2 50 28 38.0 19.5 15.6 60' 24' 52' 1' 630
1645H/HCA 16 11/2 45 26 47.0 23.5 18.8 60' 24' 52' 1' 700
CONTROL INSTRUMENTS
HCA = Heating & Cooling Air-Cooled 1650H/HCA 16 2 50 28 49.0 24.5 19.6 60' 24' 52' 1' 725
1660H/HCA 16 3 60 26 51.0 25.5 20.4 60' 24' 52' 1' 730
2460H/HCA 24 3 60 26 71.0 35.5 28.4 60' 24' 52' 1' 850
Standard
ʻLEʼ INSTRUMENT - up to 500°F: • Temperature display for to process, from process and setpoint temperatures • Status lights for power, pump heat, cool and alarm • Error lights for pump overload, and high temperature • Pump start switch • Unit on/off toggle switch • Soft key operators
1. Derate heater output by 25% for 208/3/60 operation. 2. Consult factory for 50hz operations. 3. T - to process; F - from process. 4. Approximate shipping weight.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Upgrade!
ʻHEʼ INSTRUMENT - up to 500°F: • Continuous to process temperature display • Selectable from process temperature display • Temperature display in °F or °C • Continuous setpoint temperature display • Setup display for temperature, network and machine • Capacity display for heat, cool • Ok-fault status display for temperature deviation, probe, high temperature, pump overload and phase • Alarm display • Communications display • SPI communications • Soft key operators
17 18 19 20 21
22 23
24 25
26
# 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
-
18 19 20 21 22 23
-
24 25 26 -
Phone: 317-887-0729
Description Fluid fill port Fluid pressure gauge Expansion tank Heat exchanger Cooling fan and shroud Fluid level sight glass Control Instrument Fan motor Process connections Cooling valve Transformer (with fuse) From process sensor To process sensor Discharge cylinder Power entry terminal block Suction cylinder Centrifugal pump with air-cooled seal Mercury heater contactor Pump motor starter and over load Pump motor Caster Lift-off access panel To process connection and shut-off valve From process connection and shut-off valve Air connection and valve for mold purge Unit drain
Model Designator for Regal Series Temperature Control Units RK - 1230HCA Regal Series Heater KW Pump GPM
Mode: H : Heating Only HC : Heating & Cooling HCA : Air-Cooled
Web: www.AdvantageEngineering.com
TEMPERATURE CONTROLLERS • PORTABLE CHILLERS • CENTRAL CHILLERS • PUMP TANK STATIONS • TOWER SYSTEMS • FILTERS
ADVANTAGE ENGINEERING, INC. 525 East Stop 18 Road Greenwood, IN 46142 phone: 317-887-0729 web site: www.AdvantageEngineering.com email: [email protected]
©2013 ADVANTAGE ENGINEERING, INC.
fax: 317-881-1277
Form #ADV-544 11/03 updated 01/24/2013
SINCE PRODUCT INNOVATION AND IMPROVEMENT IS OUR CONSTANT GOAL, ALL FEATURES AND SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR LIABILITY.
Control unit CPC 1-04 - digiinfo.com Heidelberg cpc manual by anna832bella - Issuu heidelberg cpc manual -This particular PDF file talk about the topic of HEIDELBERG CPC MANUAL, coupled with the whole set of accommodating tips plus more knowledge about the topic. Heidelberg cpc manual by anna832bella - Issuu The service manual is a service. Heidelberg cpc 102 manual Heidelberg Cpc 102 Manual by Imperial War Museum Heidelberg Cpc 102 Manual the author would possibly not think too much about the quality of. In the CPC 1-04 control unit, the recorded measured values are used to calculate ink zone openings and ink stripe widths. CPC 41 register control/ CPC 42.